AB驱动电抗器1321-3R160-B

  • 发布时间:2021-11-26 00:00:00,加入时间:2012年06月06日(距今4724天)
  • 地址:中国»陕西»西安:西安市灞桥区长乐东路阳光时代B座1栋西单元608室
  • 公司:陕西赛硕机电设备有限公司, 用户等级:普通会员 已认证
  • 联系:袁经理,手机:18092171377 微信:ss18092171377 QQ:260841989

罗克韦尔AB电抗器;

Allen-Bradley reactors rated 45 Amps (fundamental) and below are supplied with an integral-

mounted terminal block.

Reactors rated from 55 to 160 Amps (fundamental) are supplied with box lugs. Reactors rated 200 

to 400 Amps

(fundamental) are supplied with front facing copper tabs for cable connections. Above 400 Amps 

(fundamental), side

facing copper tabs are used for cable connections. The ‘3R’ and ‘3RA’ designations for the 

1321 line reactors indicate the

following: 3R = Open Enclosure Line Reactor and 3RA = NEMA 1 Enclosure Line Reactor. 

Line Reactor, Open Style (AC Drive Reactors), 80 Amps, 0.7 mh 1321-3LR048-B

1321反射波减少(RWR)装置

反射波现象的描述

驱动器的逆变部分不产生正弦电压,而是由直流产生的一系列

电压脉冲

公共汽车。这些脉冲沿着电机电缆传到马达,然后反射回驱动器。反射是

依赖于驱动输出电压、电

缆特性、电缆长度和电机阻抗的上升时间。如果

电压反射与另一个脉冲相结合,峰值电压可能处于破坏性的

水平。一个IGBT

驱动输出可能反映了两倍(2 pu或每单位)直流母线电压的波瞬态电压应力

自己的输出线。多

个驱动输出线在一个管道或金属托盘进一步增加输出线电压应力

在多驱动器输出线之间的接触。驱动# 1可能

有一个(+)2 pu的压力,同时驱动器2可以同时

有(-)2 pu应力。

1321-3R, 1321-3RA, and 1321-3RB Series Line Reactors

Applying Allen-Bradley Line Reactors

At the Input of the Drive

At the input of a drive, line reactors help protect against surges or spikes on the

incoming power lines and help reduce harmonic distortion.

At the Output of the Drive

In long motor lead applications, Allen-Bradley load reactors located between the

drive and motor help reduce dv/dt and motor terminal peak voltages. The use of

a load reactor also helps protect the drive from surge currents caused by rapid

changes in the load.

With Multiple Drives

Multiple drives on a common power line should each have their own line

reactor. Individual line reactors provide filtering between each drive to help

reduce any crosstalk while providing optimum surge protection for each drive.

With Multiple Motors

When more than one motor is controlled by a single drive, a single line reactor

can typically be used between the drive and all the motors. Size the line reactor

based on the total motor/load horsepower.

With Single-Phase Input

A three-phase reactor can be used for single-phase applications by routing each

of the two input power conductors to the outside two coils, and leaving the

center coil disconnected. The sum of the inductance of the two coils is the total

inductance applied to the circuit. Contact Rockwell Automation Technical

Support for assistance in specifying the proper reactor.

Eliminate Nuisance Tripping - Improve True Power Factor

Extend Semiconductor Life - Reduce Voltage Notching

Reduce Harmonic Distortion - Meet IEEE-519 or EN-61800

Protect Motors from Long Lead Effects - Reduce Surge Currents

Reduce Output Voltage dv/dt - Reduce Motor Temperature

Extend Semiconductor Life - Reduce Audible Motor Noise

低压电器设备配件 变频器电抗器 CAT 1321-3RB320-B

1321-3LR078-B

1321-3LR180-B

1321-3LRA048-B

1321-3LRA078-B

1321-3LRA180-B

1321-3R1000-B

1321-3R1000-C

1321-3R100-A

1321-3R100-B

1321-3R100-C

1321-3R12-A

1321-3R12-B

1321-3R12-C

1321-3R130-A

1321-3R130-B

1321-3R130-C

1321-3R160-A

1321-3R160-B

1321-3R160-C

1321-3R18-A

1321-3R18-B

1321-3R18-C

1321-3R1-A

1321-3R1-B

1321-3R1-C

1321-3R1-D

1321-3R200-A

1321-3R200-B

1321-3R200-C

1321-3R25-A

1321-3R25-B

1321-3R25-C

1321-3R2-A

1321-3R2-B

1321-3R2-C

1321-3R2-D

1321-3R35-A

1321-3R35-B

1321-3R35-C三相线路电抗器、开放(交流传动反应堆),35安培,1.2 mh

1321-3R45-A

1321-3R45-B

1321-3R45-C

1321-3R4-A

1321-3R4-B

1321-3R4-C

1321-3R4-D

1321-3R500-A

1321-3R500-B

1321-3R500-C

1321-3R55-A

1321-3R55-B

1321-3R55-C

1321-3R600-A

1321-3R600-B

1321-3R600-C

1321-3R750-A

1321-3R750-B

1321-3R750-C

1321-3R750-E

1321-3R80-A

1321-3R80-B

1321-3R80-C

1321-3R850-A

1321-3R850-B

1321-3R850-C

1321-3R8-A

1321-3R8-B

1321-3R8-C

1321-3R8-D

AB驱动电抗器1321-3R160-B

联系我时请说明来自志趣网,谢谢!

免责申明:志趣网所展示的信息由用户自行提供,其真实性、合法性、准确性由信息发布人负责。使用本网站的所有用户须接受并遵守法律法规。志趣网不提供任何保证,并不承担任何法律责任。 志趣网建议您交易小心谨慎。