足底热刺痛甩尾二合一

  • 发布时间:2022-02-16 16:44:36,加入时间:2018年10月09日(距今2076天)
  • 地址:中国»上海»闵行:上海市闵行区金平路328弄124号1002室
  • 公司:上海软隆科技发展有限公司, 用户等级:普通会员
  • 联系:祖翠丽,手机:18156140722 电话:021-54172191 QQ:1601927923

足底热刺痛/甩尾二合一

痛甩尾测试仪甩尾测试(tail flick )用于测试动物疼痛反应时间和动物对镇痛药物的疼痛反应极限.实验过程中,检测到动物尾部甩动后内置的计时器自动停止计时,足底热刺痛/甩尾二合一中包含

l 实时尾部温度/触发可选

l 触发温度设置功能

l 精确数字控制,时间精确度为0.01秒

l 自动切断保护功能

l 光束强度可调节,步进量1%

l 自动检测活动反应

足底热刺激痛觉实验(plantar test)用于测试镇痛药物影响无束缚大鼠对外部热刺激的反应时间,使用时先通过从爪下面的测试头发出导向光将光源移到动物爪底,通过反光镜确定位置,避免频繁弯腰和低头,方便操作,启动加热光束照射到动物爪底进行实验,足底热刺痛/甩尾二合一中已包含

l 精确数字控制, 时间精确度为0.01秒

l 光束强度可调节,步进量1%

l 加热玻璃可选配

l 测试头具有反光镜辅助观察

足底热刺痛/甩尾二合一(Combination Plantar/Tail Flick Analgesia Meter)是将以上两种设备巧妙的结合起来,用一套设备完成两种实验的性价比方案。

Plantar Test and tail Flick Test Apparatus combination system all in one ; is the only commercially available system of its kind. No need to purchase two separate systems, our combinations system enables researchers to perform both tests with this unique design. Testing properties of narcotic and stronger non-narcotic drugs on unrestrained mice and rats in plantar mode.

Plantar Test Analgesia Meter for paw stimulation can be used on 12 mice, 6 rats and other animals (cats, rabbits) unrestrained when testing for narcotic drugs. Experiments are easy to perform, simply slide the test head under test subject, align the heat source via our exclusive guide light (idle state) by the attached, adjustable, angled mirror on test head to test subject and perform tests.

Start, stop and reset of tests is done by either the push button on test head, front panel controls or supplied footswitch.

With our exclusive “idle state” of the heat source one is assured of exact placement of the heat source. Tests are performed on the plantar surface by a focused, radiant heat light source. The light beam is focused to the top of the glass and creates a 4X6mm intense spot on the paw.

Our method of visible light is superior to the infrared light method, since a user will not always know exactly where/when the test will start, causing false starts and conditioning of animals. A built-in timer displays reaction time in .01 second increments.

The height of the glass is adjustable allowing the focal point of the light to be adjusted to stimulate other body parts if needed. A Humane cutoff timer is standard. The unit can be preset for a cutoff period, at the end of which the heat source shuts off automatically if the animal has not responded, avoiding tissue damage. Our test head does not emit , clicking or whining noises that cause preconditioning of animals prior to test as with other systems on the market.