日本东丽TM820K-440 8英寸海水淡化膜解析:
海水淡化简单的说就是可以去除水中的阴离子和阳离子,同时海水淡化的方法是用电渗析,反渗透和新的热前进海水淡化。海水淡化膜的性能是检测和盐渗透性。
日本东丽TM820K-440测试条件:
操作压力 800 psi (5.52MPa)
测试液温度F (25℃)
测试液浓度 32000 mg/L (as NaCl) 5 mg/L 硼
单只膜元件水回收率 8%
测试液 pH 7
单支膜元件较低脱盐率 99.5%
较小透过水量 5,100 gpd (19.3m3/d)
日本东丽TM820K-440超高脱盐海水淡化膜水质要求:
温度条件在1到45℃之间;
pH值必须在2到11的范围之内;
有机物含量(COD,mg/L)应该小于1.5;
浊度(NTU)应该控制在1.0以下;
淤泥密度指数(SDI值)〈4.0;
余氯含量〈0.1mg/L(实际控制在0);
铁含量(mg/L):溶氧>5mg/L时,Fe<0.05;
二氧化硅含量(mg/L):浓水中Si02<100;LSI:pHb-pHs<0;
Sr、Ba等易形成难溶盐的离子:Ipb<0.8Ksp。
后三项通过添加阻垢剂可适当提高其值。
以上水质不达到会导致东丽TM820K-440海水淡化膜造成什么影响?
1、RO海水淡化膜会受金属氧化物污染;
2、胶体污染;
3、海水淡化膜结垢;
4、悬浮物污堵海水淡化膜;
5、有机物及微生物等污染,导致出水COD升高。
日本东丽TM820K-440东丽品牌海水淡化膜使用条件:
较高操作压力······························································1200psi (8.3MPa)
较高进水温度································································F(45℃)
较大进水 SDI····································································5
进水自由氯浓度·································································检测不到
连续运行时进水 pH 范围······················································2-11
化学清洗时进水 pH 范围·······················································1-12
单个膜元件较大压力损失···················································15psMPa)
单个膜组件较大压力损失····················································50psMPa)
东丽TM820K-440应用领域有哪些?
( 1 )电力工业:锅炉补给水、冷却水坝;
( 2 )电子工业:半导体工业超纯水、集成电路清洗用水、配方用水;
( 3 )食品工业:配方用水、生产用水;
( 4 )制药行业:工艺用水、制剂用水、洗涤用水、注射用水、无菌水制备;
( 5 )饮料工业:配方用水、生产用水、洗涤用水;
( 6 )化学工业:生产用水、废水处理;
( 7 )饮水工程:超纯水制备、饮用水净化;