参数
Technical Data C3MR
Accuracy class (Combined errorCn
Maximum capacity Emax 5 | 10 | 20 | 30 | 40 kg
Maximum usable load Eu 150 % Emax
Destructive load Ed >Emax
Safe side load Elq 100 % Emax
Maximum number of LC intervals nLC 3,000
Minimum LC verification interval vmin = Emax | Y Y 12,000
Rated output Cn 2.0 mV/V
Tolerance on rated output Dc < ± 10 % Cn
Zero output signal Smin < ± 5 % Cn
Creep, during 30 min. dcr < ±Cn
Temperature effect on Smin TKSmin < ±Cn / 10 K
Temperature effect on C TKC < ±Cn / 10 K
Input impedance RLC 413 ± 20 Ω
Output impedance RO 350 ± 25 Ω
Insulation impedance (100 V DC) RIS >5 GΩ
Recommended supply voltage Bu 5 … 15 V
Nominal ambient temperature range BT –10 … +40 °C
Usable ambient temperature range BTu &ndash+65 °C
Cable length 0.5 m
Cable type 6 conductor TPE cable (AWG 26),
shield grounded
Sensor material Aluminium
Protection class (acc. to IEC 529) IP67