深圳湾边贸易代理进口美国CIRS 055A及049

  • 发布时间:2022-07-15 10:01:11,加入时间:2012年07月03日(距今4351天)
  • 地址:中国»广东»深圳:深圳市龙华新区观澜大道75号田背花园E单元806
  • 公司:深圳市湾边贸易有限公司,用户等级:普通会员 已认证
  • 联系:张雪凤,手机:13714972229 微信:wanbian-B 电话:0755-86216601 QQ:1191737095

深圳湾边贸易直接进口美国 Computerized Imaging Reference Systems 公司模体:      

CIRS 055模体-三维超声校准模块, 

CIRS 055A模体-3D线形测试模块,

CIRS 044模体

CIRS 049A-弹性模体价格优惠。

美国直接进口。

 厂家:美国Computerized Imaging Reference Systems, Incorporated (美国CIRS)

For all computed tomography systems, the Food and Drug Administration recommends measuring the CT Dose Index (CTDI). Each section of the CIRS CT Dose Phantoms can provide separate dose information.  The user can also measure maximum, minimum and mid-range values of the nominal tomographic section thickness when performing dose profile measurements.

Each phantom consists of a set of nesting 15 cm thick solid PMMA disks measuring 16 cm (head) and 32 cm (body) in diameter.  The adult head disk is also suitable for pediatric body measurements. The Model 007A includes a third nesting disk measuring 10 cm in diameter for pediatric head measurements. Handles on the body and head are provided for ease in handling and maneuverability.

Through holes measuring 1.31 cm in diameter will accommodate standard CT probes. Acrylic rods are provided to plug the holes when not in use. The acrylic rods are machined to receive 1 mm diameter TLD rods.

The Model 007 & 007A are manufactured to comply with the FDA’s performance standard, 21 CFR 1020.33 that details the measurement requirements.The basic standard for ultrasound quality assurance.

The series of ultrasound phantoms, unlike human subjects or random scannable materials, offers a reliable medium which contains specific, known test objects for repeatable qualitative assessment of ultrasound scanner performance over time. This phantom is constructed from the patented solid elastic material Zerdine®.

Zerdine®, unlike other phantom materials on the market, is not affected by changes in temperature. It can be subjected to boiling or freezing conditions without sustaining significant damage. Zerdine® is also more elastic than other materials and allows more pressure to be applied to the scanning surface without subsequent damage to the material. At normal or room temperatures, the Zerdine® material found in the Model 054 will accurately simulate the ultrasound characteristics found in human liver tissue.

Designed to allow for axial resolution, lateral response width, uniformity, dead zone measurements, depth of visualization, high and low contrast mass imaging, and distance calibration.
 

Fully complies with all requirements and recommendation of the AIUM and ACR.

源自:深圳市湾边贸易有限公司
电话: 6601
QQ
备注:网络价格仅供参考,具体请来电咨询!

联系我时请说明来自志趣网,谢谢!

免责申明:志趣网所展示的信息由用户自行提供,其真实性、合法性、准确性由信息发布人负责。使用本网站的所有用户须接受并遵守法律法规。志趣网不提供任何保证,并不承担任何法律责任。 志趣网建议您交易小心谨慎。