NEMA 工业继电器
我们提供各种专门针对重载应用项目、大负载和长使用寿命设计的 NEMA 工业继电器,以满足您的工业控制应用需求。
固态型继电器
我们的固态型继电器具备固态设计固有的优点:没有可发生磨损的移动部件或触点,与 PLC 和温度控制器等工业控制器兼容。
700-SA 管座
700-SC 透明壳
700-SF 方形基座
700-SH 冰球式
700-SK 细长型
700-N 工业继电器
700-P 重载继电器
700-R 密封开关继电器
700S 重载安全控制继电器
700-MP12
700-MP16
700-MP4
700-MP8
700-N24
700-N40
700-N400A1
700-N400A2
700-N400A24
700-N5
700-NA00
700-NM200A1
700-NT
700-P000A1
700-P000B2
700-P000B22
700-P1200A1
700-P200A1
700-P400A1
700-P400A2
700-P800A1
700-PB00
700-PB40
700-PC00
700-PC40
Allen-Bradley reactors rated 45 Amps (fundamental) and below are supplied with an integral-
mounted terminal block.
Reactors rated from 55 to 160 Amps (fundamental) are supplied with box lugs. Reactors rated 200
to 400 Amps
(fundamental) are supplied with front facing copper tabs for cable connections. Above 400 Amps
(fundamental), side
facing copper tabs are used for cable connections. The ‘3R’ and ‘3RA’ designations for the
1321 line reactors indicate the
following: 3R = Open Enclosure Line Reactor and 3RA = NEMA 1 Enclosure Line Reactor.
1321-3R, 1321-3RA, and 1321-3RB Series Line Reactors
Applying Allen-Bradley Line Reactors
At the Input of the Drive
At the input of a drive, line reactors help protect against surges or spikes on the
incoming power lines and help reduce harmonic distortion.
At the Output of the Drive
In long motor lead applications, Allen-Bradley load reactors located between the
drive and motor help reduce dv/dt and motor terminal peak voltages. The use of
a load reactor also helps protect the drive from surge currents caused by rapid
changes in the load.
With Multiple Drives
Multiple drives on a common power line should each have their own line
reactor. Individual line reactors provide filtering between each drive to help
reduce any crosstalk while providing optimum surge protection for each drive.
With Multiple Motors
When more than one motor is controlled by a single drive, a single line reactor
can typically be used between the drive and all the motors. Size the line reactor
based on the total motor/load horsepower.
With Single-Phase Input
A three-phase reactor can be used for single-phase applications by routing each
of the two input power conductors to the outside two coils, and leaving the
center coil disconnected. The sum of the inductance of the two coils is the total
inductance applied to the circuit. Contact Rockwell Automation Technical
Support for assistance in specifying the proper reactor.
Eliminate Nuisance Tripping Improve True Power Factor
Extend Semiconductor Life Reduce Voltage Notching
Reduce Harmonic Distortion Meet IEEE-519 or EN-61800
Protect Motors from Long Lead Effects Reduce Surge Currents
Reduce Output Voltage dv/dt Reduce Motor Temperature